Part Number Hot Search : 
3ECSD 20204 050N03 ECWF2565 T7805 CPC7595 HX6098NL XF0506AB
Product Description
Full Text Search
 

To Download TFS411A Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  filename: tfs 411a.doc version 1.0 25.10.2004 vi telefilter filter specification tfs 411a 1/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.com vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein without notice. no liab ility is assumed as a result of their use or app lication. no rights under any patent accompany the sale of any such product(s) or infor mation. measurement condition ambient temperature: 23 c input power level: 0 dbm terminating impedance: input: 50 ? output: 50 ? characteristics remark: the maximum attenuation in the pass band is defined as the insertion loss a e . the nominal frequency f n is fixed at 411 mhz without any tolerance or limit. the values of abs olute attenuation a abs are guaranteed for the whole operating temperature range. the frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. d a t a typ. value tolerance / limit insertion loss within pb a e 2,36 db max. 4,8 db nominal frequency f n - 411 mhz passband pb 8,9 mhz f n 2,5 mhz absolute attenuation a abs f n - 410 mhz ... f n - 12,5 mhz 55 db min. 43 db f n - 12,5 mhz ... f n - 7,5 mhz 50 db min. 33 db f n + 20 mhz ... f n + 735 mhz 62 db min. 40 db f n + 735 mhz ... f n + 1235 mhz 40 db min. 30 db f n + 1235 mhz ... f n + 1535 mhz 35 db min. 15 db operating temperature range otr - - 10 c ... + 85 c storage temperature range - - 30 c ... + 85 c temperature coefficient of frequency tc f -32 ppm/k - generated: checked / approved:
filename: tfs 411a.doc version 1.0 25.10.2004 vi telefilter filter specification tfs 411a 2/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.com vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein without notice. no liab ility is assumed as a result of their use or app lication. no rights under any patent accompany the sale of any such product(s) or infor mation. filter characteristic construction and pin connection (all dimensions in mm) 50 ? test circuit 2 6 l1 l 2 1, 3, 4, 5, 7, 8 411a s44 1 ground 2 input 3 ground 4 ground 5 ground 6 output 7 ground 8 ground date code: year + week s 2004 t 2005 u 2006 ... 361 371 381 391 401 411 421 431 441 451 461 -100 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 frequency in mhz magnitude in db 407 407.8 408.6 409.4 410.2 411 411.8 412.6 413.4 414.2 415 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 frequency in mhz magnitude in db
filename: tfs 411a.doc version 1.0 25.10.2004 vi telefilter filter specification tfs 411a 3/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.com vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein without notice. no liab ility is assumed as a result of their use or app lication. no rights under any patent accompany the sale of any such product(s) or infor mation. stability characteristics after the following tests the filter shall meet the whole specification: 1. shock: 500g, 18 ms, half sine wave, 3 shocks each plane; din iec 68 t2 - 27 2. vibration: 10 hz to 500 hz, 0,35 mm or 5 g respective ly, 1 octave per min, 10 cycles per plan, 3 plans; din iec 68 t2 - 6 3. change of temperature: -55 c to 125c / 30 min. each / 10 cycles din iec 68 part 2 ? 14 test n 4. resistance to solder heat (reflow): reflow possible: twice max.; for temperature conditions refer to the attached "air reflow temperature conditions" on page 4; packing tape & reel: iec 286 ? 3, with exeption of value for n and minimum bending radius; tape type ii, embossed carrier tape with top cover tape on the upper side; max. pieces of filters peer reel: 3000 reel of empty components at start: min. 300 mm reel of empty components at s tart including leader: min. 500 mm trailer: min. 300 mm g do w ct f e g d1 p2 p1 po bo ao pull off direction pin marker typ date code ko t a c n w 1 w 2 the minimum bending radius is 45 mm. tape (all dimensions in mm) w : 12,00 0,3 po : 4,00 0,1 do : 1,50 +0,1/-0 e : 1,75 0,1 f : 5,50 0,05 g(min) : 0,75 p2 : 2,00 0,05 p1 : 8,00 0,1 d1(min) : 1,50 a o : 4,30 0,1 bo : 4,30 0,1 ct : 9,5 0,1 reel (all dimensions in mm) a : 330 w1 : 12,4 +2/-0 w2(max) : 18,4 n(min) : 50 c : 13,0 +0,5/-0,2
filename: tfs 411a.doc version 1.0 25.10.2004 vi telefilter filter specification tfs 411a 4/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.com vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein without notice. no liab ility is assumed as a result of their use or app lication. no rights under any patent accompany the sale of any such product(s) or infor mation. air reflow temperature conditions conditions exposure average ramp-up rate (30c to 217c) less than 3c/second > 100c between 300 and 600 seconds > 150c between 240 and 500 seconds > 217c between 30 and 150 seconds peak temperature max. 260c time within 5c of actual peak temperature between 10 and 30 seconds cool-down rate (peak to 50c) less than 6c/second time from 30c to peak temperature no greater than 300 seconds temperature / c time / s max. 260c 217c 10 ... 30 s 30 ... 150 s max. 300 s chip-mount air reflow profile
filename: tfs 411a.doc version 1.0 25.10.2004 vi telefilter filter specification tfs 411a 5/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.com vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein without notice. no liab ility is assumed as a result of their use or app lication. no rights under any patent accompany the sale of any such product(s) or infor mation. history version reason of changes name date 1.0 - generation of filter s pecification t. martens 21.10.2004


▲Up To Search▲   

 
Price & Availability of TFS411A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X